Pu Elements PDF
Power Unit Information
Monaco Grand Prix · 2026 · 3 June 2026 · Doc 4
2026 MONACO GRAND PRIX
07 - 09 June 2026
From The FIA Formula 1 Race Director Document 4
To All Teams, All Officials Date 03 June 2026
Time 15:03
Title Power Unit Information
Description Power Unit Information
Enclosed R06_Monaco_Power_Unit_Information.pdf
Rui Marques
The FIA Formula 1 Race Director
F1 POWER UNIT INFORMATION TO THE TEAMS AND PUMs
2026 MONACO GRAND PRIX
COMPETITION INFORMATION
| ROUND No. | R06 |
|---|---|
| VENUE | Monte Carlo |
| CENTRELINE | 3.337 km |
| FORMAT | Standard |
| DATE | 05-07 June |
POWER AND ENERGY LIMITS
| Article C5.2.10 Maximum Recharge per lap | Article C5.12.8 Maximum PU Power Reduction Rate | |||||
|---|---|---|---|---|---|---|
| Race | Qualifying | Free Practice sessions | Out laps other than in Race | Power Limited Distance | Rate Limit | |
| Overtake not active | Overtake active | |||||
| 8.5 MJ | 9.0 MJ | 9.0 MJ | 9.0 MJ | 9.0 MJ | 1388 m | 100 kW/s |
| Article C5.2.8 Maximum DC power of ERS-K function of car speed | 400 350 )Wk( Rev 1 - Standard 300 Rev 1 - Overtake 250 rewoP 200 CD 150 KUGM 100 50 350 )Wk( 300 250 rewoP 200 CD 150 KUGM 100 50 | Rev 1 - S Rev 1 - O | tandard vertake | |||
|---|---|---|---|---|---|---|
| Sprint & Race | Any Practice Session incl. Qualifying Sessions | |||||
| Main Overtaking Zones | Other parts of the Lap | |||||
| Overtake not active | Overtake active | |||||
| Rev 1 - Standard | Rev 1 - Overtake | |||||
| No such sectors defined | Rev 1 - Overtake | 0 180 200 220 240 260 280 300 320 vCar (km/h) |
IDENTIFICATION OF SECTORS WHERE EXCEPTIONS APPLY
| Article C5.2.8iii Sectors where the alternative power curve defined above applies in Sprint & Race | Article C5.12.4 Sectors where the PU power reduction at the start of a Power Limited Pending period can be greater than 150kW (sectors indicated by [ ] are for SQ and Q only) | Article C5.12.5 Sectors where a reset of MGUK power reduction is permitted (sectors indicated by [ ] are for SQ and Q only) | ||||
|---|---|---|---|---|---|---|
| Identification of Sectors | Lap distance window [m] | Identification of Sectors | Lap distance window [m] | Maximum PU power reduction permitted | Identification of Sectors | Lap distance window [m] |
| - | - | [Exit T19] | [2980-3200] | [350kW] | [Exit T19] | [3070-3400] |
| Article C5.12.7 | ||
|---|---|---|
| Sectors with a higher speed threshold | ||
| Identification of Sectors | Lap distance window [m] | Speed threshold |
| - | - | - |
| OVERTAKE | ||
|---|---|---|
| Article B7.2 | ||
| Detection Gap | Detection Line [sLap & Loop] (Art. B7.2.1b.viii) | Activation Line [sLap & Loop] (Art. B7.2.1b.ix) |
| 1.0 s | 2805 m L19 | 2950 m L20/SC1 |